BDA Directory List

Product Title: ADRF PSR-78-9533-X (2W Channelized Digital Repeater for Public Safety - 700/800 MHz)
Supported Bands: 800
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 805 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 775 MHz
Uplink Composite Power in dBm: 30
Downlink Composite Power in dBm: 33
Power Consumption (Input Power): 150
2524 Listing Status: Classified
2524 NRTL for Listed Products: UL
2524 Certification Date:
STD 2524 Certification Image:
STD 2524 Comments: Currently MET Classified for UL2524 Fire & Shock Final stages of UL2524 Listed status with UL Labs
Other Certifications: - NFPA & IFC Code Compliant - FirstNet Compliant - Supports FCC Part 90 Class A Narrowband OR Class B wideband repeater designations
Notes: The ADRF PSR-78-9533-X is a revolutionary digital public safety repeater designed to protect the lives of first responders and building occupants. www.adrftech.com


Product Title: Comba Public Safety 33dBm Class B Dual Band 800MHz BDA (AC/DC)
Supported Bands: 800
Class: B
Uplink Frequencies in MHz: From: MHz To: MHz
Downlink Frequencies in MHz: From: MHz To: MHz
Uplink Composite Power in dBm:
Downlink Composite Power in dBm:
Power Consumption (Input Power):
2524 Listing Status: Listed
2524 NRTL for Listed Products: SGS
2524 Certification Date: Friday, August 16, 2019
STD 2524 Certification Image: View Certificate
STD 2524 Comments:
Other Certifications: UL 60950-1 & UL 60950-22 Compliant
Website:
Notes:


Product Title: ADRF PSR-78-9537-X (5W Channelized Digital Repeater for Public Safety - 700/800 MHz)
Supported Bands: 800
Class: B
Uplink Frequencies in MHz: From: 806 MHz To: 816 MHz
Downlink Frequencies in MHz: From: 851 MHz To: 861 MHz
Uplink Composite Power in dBm: 30
Downlink Composite Power in dBm: 37
Power Consumption (Input Power): 222
2524 Listing Status: Classified
2524 NRTL for Listed Products: UL
2524 Certification Date:
STD 2524 Certification Image:
STD 2524 Comments: Currently MET Classified for UL2524 Fire & Shock Final stages of UL2524 Listed status with UL Labs
Other Certifications: - NFPA & IFC Code Compliant - FirstNet Compliant - Supports FCC Part 90 Class A Narrowband OR Class B wideband repeater designations
Notes: The ADRF PSR - 78 - 9537-X is a revolutionary digital public safety repeater designed to protect the lives of first responders and building occupants. www.adrftech.com


Product Title: TruePath - Class B 700 or 800 MHz Public Safety BDA, 1/2 Watt, DC
Supported Bands: 700, 800, Band 14
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 896 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 27
Power Consumption (Input Power): 160
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 31, 2023
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Investigated to UL2524 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier
Other Certifications: CAN/CSA-C22.2 No. 62638-1, FCC Part 20 Part 90
Website: 7831851-0022
Notes: Wireless Supply also offers our BDA Products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to a buildings fire alarm panel


Product Title: TruePath - Class B 700 or 800 MHz Public Safety BDA, 2 Watts, AC
Supported Bands: 700, 800, Band 14
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 896 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 33
Power Consumption (Input Power): 160
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 31, 2023
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Investigated to UL2524 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier
Other Certifications: CAN/CSA-C22.2 No. 62638-1, FCC Part 20 Part90
Website: 7831851-0001
Notes: Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to the buildings fire alarm panel


Product Title: Comba Public Safety 27dBm Class B Dual Band 800MHz BDA (AC/DC)
Supported Bands: 800
Class: B
Uplink Frequencies in MHz: From: MHz To: MHz
Downlink Frequencies in MHz: From: MHz To: MHz
Uplink Composite Power in dBm:
Downlink Composite Power in dBm:
Power Consumption (Input Power):
2524 Listing Status: Listed
2524 NRTL for Listed Products: SGS
2524 Certification Date: Friday, August 16, 2019
STD 2524 Certification Image: View Certificate
STD 2524 Comments:
Other Certifications: UL 60950-1 & UL 60950-22 Compliant
Website:
Notes:


Product Title: Comba Public Safety 37dBm Class B Dual Band 800MHz BDA (AC/DC)
Supported Bands: 800
Class: B
Uplink Frequencies in MHz: From: MHz To: MHz
Downlink Frequencies in MHz: From: MHz To: MHz
Uplink Composite Power in dBm:
Downlink Composite Power in dBm:
Power Consumption (Input Power):
2524 Listing Status: Listed
2524 NRTL for Listed Products: SGS
2524 Certification Date: Friday, August 16, 2019
STD 2524 Certification Image: View Certificate
STD 2524 Comments:
Other Certifications: UL 60950-1 & UL 60950-22 Compliant
Website:
Notes:


Product Title: TruePath - Class B 700 or 800 MHz Public Safety BDA, 1/2 Watt, AC
Supported Bands: 700, 800, Band 14
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 896 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 27
Power Consumption (Input Power):
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 31, 2023
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Investigated to UL2524 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier
Other Certifications: CAN/CSA-C22.2 No. 62638-1, FCC Part 20 Part 90
Website: 7831851-0012
Notes: Wireless Supply also offers our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to a buildings fire alarm panel


Product Title: Fiplex DH7S-A-S33B - DIGITAL SIGNAL BOOSTER. PS 800 MHz, Single Band +33dBm, Class B, 2 Adj sub band, NFPA, AC.
Supported Bands: 800
Class: B
Uplink Frequencies in MHz: From: 806 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 851 MHz To: 869 MHz
Uplink Composite Power in dBm: 24
Downlink Composite Power in dBm: 33
Power Consumption (Input Power): 80
2524 Listing Status: Listed
2524 NRTL for Listed Products: SGS
2524 Certification Date: Thursday, November 12, 2020
STD 2524 Certification Image: View Certificate
STD 2524 Comments:
Other Certifications: FCC, NFPA, Buy American Compliant
Notes: www.fiplex.com


Product Title: TruePath - Class B 700 or 800 MHz Public Safety BDA, 2 Watts, DC
Supported Bands: 700, 800, Band 14
Class: B
Uplink Frequencies in MHz: From: 788 MHz To: 824 MHz
Downlink Frequencies in MHz: From: 758 MHz To: 896 MHz
Uplink Composite Power in dBm: 27
Downlink Composite Power in dBm: 33
Power Consumption (Input Power): 160
2524 Listing Status: Listed
2524 NRTL for Listed Products: UL
2524 Certification Date: Wednesday, May 31, 2023
STD 2524 Certification Image: View Certificate
STD 2524 Comments: Investigated to UL2514 - 2nd Edition Revised 2019-02-28, Bi-directional amplifier
Other Certifications: CAN/CSA-C22.2 No.62638-1, FCC Part 20 Part 90
Website: 7831851-0002
Notes: Wireless Supply also offer our BDA products as a kit which includes the BBU, annunciator, and alarm junction boxes for connection to a buildings fire alarm panel